Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Am J Dent ; 36(5): 227-232, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37865809

RESUMO

PURPOSE: To evaluate staining- and aging-dependent changes in the color and translucency of 3D-printed resin-modified ceramics (RMC). METHODS: Specimens (n= 5 per condition and material) were fabricated from test materials: Permanent Crown Resin (PCR), Crowntec (CT), Vita Enamic (VE) and Tetric CAD (TC). Specimens were stained in wine, coffee, tea, and water (control) and exposed to artificial accelerated aging (AAA). Color measurements were obtained using a spectrophotometer at baseline (T0) and at 3.5 (T1) and 7 (T2) days after immersion. For AAA, measurements were obtained at baseline (T0) and after exposure to controlled irradiance of 150 kJ/m² (T1) and 300 kJ/m² (T2). Mean and standard deviations were calculated on CIEDE2000 color differences (ΔE00), translucency parameter (TP00) and treatment-dependent changes in the translucency parameter (ΔTP0 0). Differences between materials and test conditions were tested by one-way ANOVA (α= 0.05). Results were additionally interpreted using visual color difference thresholds in dentistry ΔE00= 0.8 for the 50:50 perceptibility threshold (PT) and ΔE00= 1.8 for the 50:50 acceptability threshold (AT). ΔTP00 values were interpreted using 5058;50 TPT00= 0.6 and 50:0% TAT00= 2.6. RESULTS: Statistically significant differences were found among the materials when exposed to the different test conditions. At the T0-T1 time interval, the highest color difference was found with wine (0.1-2.2) on all materials except CT, which showed the highest ΔE00 with AAA (2.5). The second highest color differences were obtained upon exposure to AAA (0.2-2.5) and tea (0.5-1.1). The TP00 at baseline ranged from 5.1 to 9.8. Significant differences in ΔTP00 were found among the tested materials and staining/aging conditions, but no significant differences were found among the staining/aging intervals (T0-T1, T0-T2 and T1-T2). CLINICAL SIGNIFICANCE: Staining- and artificial aging-dependent changes of 3D-printed and milled resin modified ceramics used for definitive restorations could represent a challenge in terms of restoration acceptability or dissatisfaction. Staining and aging conditions produced significant color changes, while translucency changes were not significant.


Assuntos
Cerâmica , Chá , Cor , Teste de Materiais , Coloração e Rotulagem , Propriedades de Superfície , Impressão Tridimensional , Desenho Assistido por Computador
2.
ACS Infect Dis ; 7(9): 2591-2595, 2021 09 10.
Artigo em Inglês | MEDLINE | ID: mdl-34437808

RESUMO

The main protease (Mpro) of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the cause of coronavirus disease (COVID-19), is an ideal target for pharmaceutical inhibition. Mpro is conserved among coronaviruses and distinct from human proteases. Viral replication depends on the cleavage of the viral polyprotein at multiple sites. We present crystal structures of SARS-CoV-2 Mpro bound to two viral substrate peptides. The structures show how Mpro recognizes distinct substrates and how subtle changes in substrate accommodation can drive large changes in catalytic efficiency. One peptide, constituting the junction between viral nonstructural proteins 8 and 9 (nsp8/9), has P1' and P2' residues that are unique among the SARS-CoV-2 Mpro cleavage sites but conserved among homologous junctions in coronaviruses. Mpro cleaves nsp8/9 inefficiently, and amino acid substitutions at P1' or P2' can enhance catalysis. Visualization of Mpro with intact substrates provides new templates for antiviral drug design and suggests that the coronavirus lifecycle selects for finely tuned substrate-dependent catalytic parameters.


Assuntos
COVID-19 , Proteases 3C de Coronavírus/metabolismo , SARS-CoV-2 , Antivirais , Humanos , Peptídeo Hidrolases , Proteínas não Estruturais Virais
3.
J Prosthodont ; 30(9): 804-810, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33486808

RESUMO

PURPOSE: To evaluate the wear resistance of a recently developed three-dimensional (3D) printed denture teeth resin compared to three commercially available prefabricated denture teeth. MATERIALS AND METHODS: A total of 88 maxillary first molar denture teeth were evaluated: C (Classic; Dentsply Sirona, York, PA), DCL (SR Postaris DCL; Ivoclar Vivadent, Schaan, Liechtenstein), IPN (Portrait IPN; Dentsply Sirona, York, PA), and F (Denture Teeth A2 Resin 1 L; Formlabs, Somerville, MA). The 3D printed denture tooth specimens were fabricated from a methacrylate-based photopolymerizing resin using stereolithography (SLA). Denture teeth were subjected to a three-body wear test with a poly(methylmethacrylate) (PMMA) abrasive slurry. A Leinfelder-style four station wear apparatus with custom bullet-shaped milled zirconia styli was utilized with a load force of 36-40 N at 1.7 Hz for 200,000 cycles. Maximum depth of wear was measured using a lab grade scanner and analyzing software program. Data were analyzed using a one-way ANOVA followed by the Tukey's Multiple Comparisons post hoc test (α = 0.05). RESULTS: A statistically significant difference in depth of wear was found between denture tooth materials (p < 0.001). The mean vertical depth of wear for the 3D printed denture teeth (0.016 ± 0.010 mm) was statistically significantly less than the prefabricated denture teeth. The highly cross-linked denture teeth, DCL (0.036 ± 0.011 mm) and IPN (0.035 ± 0.014 mm), exhibited statistically significantly less wear than the conventional acrylic denture teeth. The conventional acrylic denture teeth demonstrated the greatest wear (0.058 ± 0.014 mm). No significant difference in depth of wear was found between DCL and IPN (p > 0.001). CONCLUSIONS: Denture tooth material significantly influences the depth of wear. The 3D printed denture teeth demonstrated superior wear resistance compared to the commercially available prefabricated denture teeth when opposed to zirconia. Denture teeth fabricated with SLA technology may have a promising future in prosthetic dentistry.


Assuntos
Desgaste de Restauração Dentária , Dentaduras , Teste de Materiais , Impressão Tridimensional , Propriedades de Superfície , Zircônio
4.
Nat Chem Biol ; 16(5): 529-537, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32152540

RESUMO

Combination antiretroviral therapy has transformed HIV-1 infection, once a fatal illness, into a manageable chronic condition. Drug resistance, severe side effects and treatment noncompliance bring challenges to combination antiretroviral therapy implementation in clinical settings and indicate the need for additional molecular targets. Here, we have identified several small-molecule fusion inhibitors, guided by a neutralizing antibody, against an extensively studied vaccine target-the membrane proximal external region (MPER) of the HIV-1 envelope spike. These compounds specifically inhibit the HIV-1 envelope-mediated membrane fusion by blocking CD4-induced conformational changes. An NMR structure of one compound complexed with a trimeric MPER construct reveals that the compound partially inserts into a hydrophobic pocket formed exclusively by the MPER residues, thereby stabilizing its prefusion conformation. These results suggest that the MPER is a potential therapeutic target for developing fusion inhibitors and that strategies employing an antibody-guided search for novel therapeutics may be applied to other human diseases.


Assuntos
Fármacos Anti-HIV/química , Fármacos Anti-HIV/farmacologia , Proteína gp41 do Envelope de HIV/química , Proteína gp41 do Envelope de HIV/metabolismo , Internalização do Vírus/efeitos dos fármacos , Sítios de Ligação , Antígenos CD4/metabolismo , Membrana Celular/metabolismo , Dequalínio/química , Dequalínio/farmacologia , Avaliação Pré-Clínica de Medicamentos/métodos , Polarização de Fluorescência , Células HEK293 , Proteína gp41 do Envelope de HIV/genética , HIV-1/patogenicidade , Humanos , Interações Hidrofóbicas e Hidrofílicas , Espectroscopia de Ressonância Magnética , Estrutura Molecular , Mutação , Bibliotecas de Moléculas Pequenas/química , Bibliotecas de Moléculas Pequenas/farmacologia , Relação Estrutura-Atividade , Ressonância de Plasmônio de Superfície
5.
Am J Orthod Dentofacial Orthop ; 156(1): 61-66, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31256840

RESUMO

OBJECTIVE: The objectives of this research were to investigate and compare general and pediatric dentists' subjective judgments of orthodontic case complexity and to determine how their perceptions of case complexity influence their decisions to refer the patient to an orthodontist. METHODS: Twenty pediatric dentists and 21 general dentists participated in the study. Pretreatment orthodontic records of 20 patients with a variety of malocclusions and a range of American Board of Orthodontics Discrepancy Index (DI) scores were used. Respondents were asked about their background and training in orthodontics. They were also asked to identify the subjective complexity of each case with the use of a 100-point visual analog scale (VAS) and whether they would refer the patient to an orthodontic specialist. A mixed-model multivariate data analysis was used to evaluate the subjective case complexity with the use of fixed factors such as DI score, type of panel member, experience, annual continuing education rate, and gender. Generalized linear mixed models were used to investigate the referral patterns of the general dentists and pediatric dentists. Level of significance was set at P < 0.05 for all statistical analyses. RESULTS: General dentists appeared to provide more overall orthodontic treatment than pediatric dentists; many general dentists provide limited orthodontic treatment and clear aligner therapy (P < 0.05). The perceived complexity score for cases was not significantly different between the 2 groups (P = 0.82). The association between DI score and perceived complexity was similar in both groups (P = 0.183) and there was a high correlation between DI and VAS score in the sample (r = 0.71; 95% Cl 0.38-0.87). Pediatric dentists had higher referral rates for cases with DI scores both below and above 20. Significant differences were noted between the pediatric and general dentists in the individual case referral decision as evaluated by the DI (P < 0.037) and VAS (P < 0.042) scores. CONCLUSIONS: General dentists provided more orthodontic care than the pediatric dentists. Both groups identified case complexity similarly, with only minor differences, but pediatric dentists had higher referral rates to orthodontic specialists regardless of the initial case complexity.


Assuntos
Tomada de Decisões , Odontólogos , Clínicos Gerais , Índice de Necessidade de Tratamento Ortodôntico , Ortodontistas , Encaminhamento e Consulta/normas , Atitude do Pessoal de Saúde , Odontólogos/educação , Clínicos Gerais/educação , Humanos , Julgamento , Má Oclusão/terapia , Análise Multivariada , Ortodontia Corretiva , Seleção de Pacientes , Projetos de Pesquisa , Inquéritos e Questionários
6.
J Dent Child (Chic) ; 84(3): 115-119, 2017 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-29282166

RESUMO

PURPOSE: The purpose of this study was to determine gloss and surface roughness (Ra) of pediatric anterior zirconia crowns. METHODS: Gloss of labial and lingual surfaces of pediatric anterior zirconia crowns from three manufacturers was measured on 20 specimens using a small area gloss meter on each. Ra (µm) was measured using a contact-type surface profilometer. Data were evaluated by analysis of variance and pair-wise comparison at the 0.05 level of significance. RESULTS: There were statistically significant interactions between surface location and crown type for both gloss and Ra scores. NuSmile had higher mean gloss scores and lower mean Ra scores than both Kinder Krowns and EZCrowns. Kinder Krowns showed lower mean gloss scores and higher Ra scores than other crown groups. CONCLUSION: Among all crowns, there was a trend of higher mean gloss paired with lower mean surface roughness, and lower mean gloss paired with higher mean Ra. Hand smoothed followed by mechanically polished zirconia crowns (NuSmile) displayed the highest mean gloss and lowest mean Ra compared to hybrid polishedglazed zirconia crowns (Kinder Krowns, EZCrowns). Of the hybrid polished-glazed zirconia crowns, Kinder Krowns displayed the lowest mean gloss and highest mean Ra.


Assuntos
Coroas , Materiais Dentários/química , Zircônio/química , Criança , Polimento Dentário , Planejamento de Prótese Dentária , Humanos , Propriedades de Superfície
7.
Science ; 353(6295): 172-175, 2016 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-27338706

RESUMO

HIV-1 envelope spike (Env) is a type I membrane protein that mediates viral entry. We used nuclear magnetic resonance to determine an atomic structure of the transmembrane (TM) domain of HIV-1 Env reconstituted in bicelles that mimic a lipid bilayer. The TM forms a well-ordered trimer that protects a conserved membrane-embedded arginine. An amino-terminal coiled-coil and a carboxyl-terminal hydrophilic core stabilize the trimer. Individual mutations of conserved residues did not disrupt the TM trimer and minimally affected membrane fusion and infectivity. Major changes in the hydrophilic core, however, altered the antibody sensitivity of Env. These results show how a TM domain anchors, stabilizes, and modulates a viral envelope spike and suggest that its influence on Env conformation is an important consideration for HIV-1 immunogen design.


Assuntos
Proteína gp41 do Envelope de HIV/química , HIV-1/fisiologia , Fusão de Membrana , Internalização do Vírus , Arginina/química , Arginina/genética , Anticorpos Anti-HIV/imunologia , Proteína gp41 do Envelope de HIV/genética , Proteína gp41 do Envelope de HIV/imunologia , HIV-1/imunologia , Bicamadas Lipídicas/química , Mutação , Ressonância Magnética Nuclear Biomolecular , Multimerização Proteica , Estabilidade Proteica , Estrutura Terciária de Proteína
8.
J Dent Educ ; 79(9): 1101-7, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26329035

RESUMO

The aim of this study was to examine the impact of psychomotor operative video demonstrations on first-year dental students who are performing specific procedures for the first time in a preclinical setting. The class was randomly divided into two groups, and three restorative procedures were selected. On the date on which each procedure was to be performed in the preclinical laboratory for the first time, one group (experimental, n=50) was shown a technique video for that specific procedure immediately before commencing the exercise; the control cohort (n=50) did not view the video. Technical performance on procedures was evaluated by students and two calibrated and blinded examiners. The students' perceptions of the experience were also collected in a survey. All first-year students participated in the study, for a 100% response rate. A Mann-Whitney U test did not show any group differences in technical performance (mean values on preparation: 77.1 vs. 77.8; amalgam: 82.7 vs. 82.8; composite: 79.7 vs. 78.0). A Spearman rho test revealed a significantly higher correlation in 13 out of 25 evaluation categories between student self-assessment and blinded examiner assessment for the experimental group. A chi-square test of questionnaire responses revealed a positive student perception of administering these videos for the preparation (X(2)=4.8, p<0.03), the amalgam restoration (X(2)=12.4, p<0.001), and the composite restoration (X(2)=11.3, p<0.001). The psychomotor video demonstrations did not immediately improve student performance on preclinical operative procedures, but they were well received by students and augmented self-assessment ability. These findings suggest that videos can be a useful teaching aid in a preclinical environment, especially regarding comprehension of concepts.


Assuntos
Dentística Operatória/educação , Educação em Odontologia , Avaliação Educacional/métodos , Estudantes de Odontologia , Materiais de Ensino , Gravação em Vídeo , Atitude , Estudos de Coortes , Resinas Compostas/química , Compreensão , Amálgama Dentário/química , Preparo da Cavidade Dentária/métodos , Materiais Dentários/química , Restauração Dentária Permanente/métodos , Tecnologia Educacional , Humanos , Desempenho Psicomotor/fisiologia , Programas de Autoavaliação , Método Simples-Cego
9.
J Med Case Rep ; 9: 14, 2015 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-25649957

RESUMO

INTRODUCTION: Peripheral giant cell granuloma and peripheral ossifying fibroma are clinicopathologically distinct gingival lesions. Both are included in clinical differential diagnoses of common benign and reactive gingival epulides in humans. It is often impossible to make a clinical distinction between the two entities, thereby making definitive diagnosis dependent on histopathologic features. While our search of the English literature revealed several reports of peripheral giant cell granuloma with 'bone formation', we were unable to identify any reports of hybrid peripheral ossifying fibroma-peripheral giant cell granulomas. CASE PRESENTATION: We report a case of a 44-year-old Caucasian man presenting with a three-month history of swelling of his right posterior mandible, related to an area of previous dental implant restoration. A clinical examination revealed modest extraoral facial swelling of his right posterior mandible, while an intraoral examination showed a 45 × 25 × 15 mm sessile, lobular soft tissue mass of the right posterior mandibular gingiva. The mucosal covering of the lesion exhibited focal surface ulceration. A panoramic radiograph showed two implants at the vicinity of the lesion with no other significant findings. An excisional biopsy of the lesion followed by histopathologic examination of the biopsy specimen revealed salient and distinctive features of peripheral giant cell granuloma and of peripheral ossifying fibroma, estimated at near equal proportions. This raises the possibility of a hybrid odontogenic lesion. CONCLUSION: The presentation of this lesion, with areas of peripheral giant cell granuloma along with a distinct area of extensive osseous formation and stroma reminiscent of a peripheral ossifying fibroma, justifies consideration of this as a possible hybrid lesion. Although the biologic behavior of a combined lesion is not anticipated to deviate significantly from that of either of the single entities, this case resurrects an enduring debate as to whether peripheral giant cell granuloma and peripheral ossifying fibroma are simply parts of a disease spectrum, or whether some of these lesions represent true hybrid lesions. It is therefore recommended that more cases with histopathologic features similar to the lesion in our case be reported in the literature to further elucidate the histogenesis of these lesions.


Assuntos
Fibroma Ossificante/complicações , Fibroma Ossificante/diagnóstico , Neoplasias Gengivais/complicações , Neoplasias Gengivais/diagnóstico , Granuloma de Células Gigantes/complicações , Granuloma de Células Gigantes/diagnóstico , Adulto , Biópsia , Diagnóstico Diferencial , Gengiva/diagnóstico por imagem , Gengiva/patologia , Humanos , Masculino , Mandíbula/diagnóstico por imagem , Mandíbula/patologia , Metaplasia , Radiografia
10.
Gen Dent ; 62(1): e36-9, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24401363

RESUMO

Historically, traditional elastomeric impression techniques for indirect fixed procedures have presented challenges for the operator, laboratory, and patient. Recent digital impression unit technology offers a compelling alternative to elastomeric impressions. The iTero system applies parallel confocal imaging to create a virtual impression that can be easily captured, edited, and uploaded electronically to the dental laboratory. Computer-aided design/computer-aided manufacturing technology is applied to the virtual impression to create an unlimited number of identical polyurethane models. This case report is presented from the perspectives of the clinicians and the laboratory technician using an iTero system to treat a left mandibular second premolar with a resin composite inlay.


Assuntos
Resinas Compostas/uso terapêutico , Restaurações Intracoronárias/métodos , Dente Pré-Molar/cirurgia , Desenho Assistido por Computador , Coroas , Restauração Dentária Permanente/métodos , Humanos , Masculino , Pessoa de Meia-Idade
11.
J Virol ; 88(2): 1249-58, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24227838

RESUMO

Induction of broadly neutralizing antibodies (bNAbs) is an important goal for HIV-1 vaccine development. Two autoreactive bNAbs, 2F5 and 4E10, recognize a conserved region on the HIV-1 envelope glycoprotein gp41 adjacent to the viral membrane known as the membrane-proximal external region (MPER). They block viral infection by targeting a fusion-intermediate conformation of gp41, assisted by an additional interaction with the viral membrane. Another MPER-specific antibody, 10E8, has recently been reported to neutralize HIV-1 with potency and breadth much greater than those of 2F5 or 4E10, but it appeared not to bind phospholipids and might target the untriggered envelope spikes, raising the hope that the MPER could be harnessed for vaccine design without major immunological concerns. Here, we show by three independent approaches that 10E8 indeed binds lipid bilayers through two hydrophobic residues in its CDR H3 (third heavy-chain complementarity-determining region). Its weak affinity for membranes in general and preference for cholesterol-rich membranes may account for its great neutralization potency, as it is less likely than other MPER-specific antibodies to bind cellular membranes nonspecifically. 10E8 binds with high affinity to a construct mimicking the fusion intermediate of gp41 but fails to recognize the envelope trimers representing the untriggered conformation. Moreover, we can improve the potency of 4E10 without affecting its binding to gp41 by a modification of its lipid-interacting CDR H3. These results reveal a general mechanism of HIV-1 neutralization by MPER-specific antibodies that involves interactions with viral lipids.


Assuntos
Anticorpos Neutralizantes/imunologia , Anticorpos Anti-HIV/imunologia , Proteína gp41 do Envelope de HIV/química , Proteína gp41 do Envelope de HIV/imunologia , Infecções por HIV/imunologia , HIV-1/imunologia , Motivos de Aminoácidos , Anticorpos Neutralizantes/química , Anticorpos Neutralizantes/genética , Linhagem Celular , Membrana Celular/virologia , Regiões Determinantes de Complementaridade/química , Regiões Determinantes de Complementaridade/genética , Regiões Determinantes de Complementaridade/imunologia , Anticorpos Anti-HIV/química , Anticorpos Anti-HIV/genética , Proteína gp41 do Envelope de HIV/genética , Infecções por HIV/virologia , HIV-1/química , HIV-1/genética , Humanos , Testes de Neutralização
12.
Tex Dent J ; 128(6): 541-5, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21827038

RESUMO

UNLABELLED: The purpose of this study was to compare the force loss of 1/4 inch (6.35mm) 3.5oz (99g) medium latex elastics from Ormco Corp. to non-latex elastics from ClassOne Orthodontics and Phoenix after being cycled between different temperatures. Elastics were stretched to 1.57 inches (40mm) on jigs and cycled in water baths for 4 minutes at 5 degrees C and 37 degrees C, 21 degrees C and 37 degrees C, 5 degrees C and 50 degrees C, 37 degrees C and 50 degrees C, and a control group was held at 3 degrees 7 degrees C. The force produced by new elastics and elastics after incubation was measured using a Mini 44 Instron. RESULTS: All elastics experienced increased force loss that correlated with increased temperatures with the exception of Ormco latex elastics. The latex elastics had the greatest force loss upon cycling between 5 degrees C and 50 degrees C while the non-latex elastics had the greatest force loss while cycling between 37 degrees C and 50 degrees C. All elastics were strongest when cycled between 5 degrees C and 37 degrees C. CONCLUSION: This study suggests that hot liquids reduce the force of latex and non-latex elastics even when cycled between hot temperatures for brief periods of time.


Assuntos
Elastômeros , Aparelhos Ortodônticos , Análise do Estresse Dentário , Elasticidade , Temperatura Alta , Humanos , Látex , Teste de Materiais , Estresse Mecânico
13.
Tex Dent J ; 128(3): 267-75, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21667823

RESUMO

This study investigated whether three different color change light-cured orthodontic bonding adhesives have comparable shear bond strengths to a conventional light-cured orthodontic bonding adhesive. The sample of 240 bovine incisors was divided into four groups of 60 each. Each group tested one of four orthodontic bonding adhesives: 3M Unitek Transbond PLUS, Ormco Gréngloo, Ormco Blúgloo, and 3M Unitek Transbond XT (control). The four groups were further divided into two subgroups of 30 with shear bond strength tested at two different times (15 minutes and 24 hours) post-bond. The shear bond strength was measured on a universal testing machine. The data were analyzed by two-way analysis of variance and post-hoc comparisons (Fisher's PLSD) at the 0.05 level of significance. The average shear bond strength was greater at 24 hours than at 15 minutes for Transbond PLUS, Blúgloo, and Transbond XT. For Gréngloo, the average shear bond strength was greater at 15 minutes than at 24 hours. Gréngloo tested at 15 minutes had the highest average shear bond strength. Gréngloo tested at 24 hours had the lowest average shear bond strength. All four orthodontic bonding adhesives demonstrated bond strengths considered to be clinically acceptable for orthodontic purposes.


Assuntos
Cura Luminosa de Adesivos Dentários/métodos , Braquetes Ortodônticos , Cimentos de Resina/química , Resistência ao Cisalhamento , Análise de Variância , Animais , Bovinos , Análise do Estresse Dentário , Teste de Materiais
14.
Clin Cosmet Investig Dent ; 3: 39-44, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-23674913

RESUMO

BACKGROUND: The purpose of this study was to compare the shear bond strengths of two color-change adhesives with a commonly used conventional light-cure adhesive while using a self-etching primer, and to compare any changes in shear bond strengths over time. METHODS: One hundred and eighty extracted bovine incisors were randomly divided into nine groups of 20 teeth each. The teeth were prepared with a self-etching primer (Transbond™ Plus) Metal lower incisor brackets were bonded directly to each tooth with two different color-change adhesives (TransbondPlus and Grengloo™) and a control (Transbond XT). The teeth were debonded at three different time points (15 minutes, 24 hours, 1 week) using an Instron at 1.0 mm/min. The teeth that were to be debonded at 24 hours and 1 week were stored in distilled water at 37°C to simulate the oral environment. The data were analyzed by two-way analysis of variance and with Fisher's protected least-significant difference multiple comparisons test at the P < 0.05 level of significance. Adhesive remnant index (ARI) scores were calculated for each debonded tooth. RESULTS: Transbond Plus at 1 week had the highest mean shear bond strength (14.7 mPa). Grengloo tested at 24 hours had the lowest mean shear bond strength (11.3 mPa). The mean shear bond strengths for the remaining seven groups had a range of 12-14.5 mPa. Grengloo had >80% samples presenting with an ARI score of 1 at all times. Interestingly, both Transbond groups had ARI scores of 3 in more than 50% of their samples. CONCLUSION: Time had no significant effect on the mean shear bond strength of Transbond XT, Grengloo, or Transbond Plus adhesive.

15.
Nat Struct Mol Biol ; 17(12): 1486-91, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21076402

RESUMO

HIV-1 envelope glycoprotein gp41 undergoes large conformational changes to drive fusion of viral and target cell membranes, adopting at least three distinct conformations during the viral entry process. Neutralizing antibodies against gp41 block HIV-1 infection by targeting gp41's membrane-proximal external region in a fusion-intermediate state. Here we report biochemical and structural evidence that non-neutralizing antibodies, capable of binding with high affinity to an immunodominant segment adjacent to the neutralizing epitopes in the membrane-proximal region, recognize a gp41 conformation that exists only when membrane fusion is complete. We propose that these non-neutralizing antibodies are induced in HIV-1-infected individuals by gp41 in a triggered, postfusion form and contribute to production of ineffective humoral responses. These results have important implications for gp41-based vaccine design.


Assuntos
Anticorpos Neutralizantes/química , Anticorpos Antivirais/química , Proteína gp41 do Envelope de HIV/química , Proteína gp41 do Envelope de HIV/imunologia , HIV-1/imunologia , Anticorpos Monoclonais/química , Anticorpos Monoclonais/fisiologia , Anticorpos Neutralizantes/imunologia , Anticorpos Antivirais/imunologia , Cristalografia por Raios X , Humanos , Imunidade Humoral , Fragmentos Fab das Imunoglobulinas/química , Fragmentos Fab das Imunoglobulinas/fisiologia , Modelos Moleculares , Estrutura Terciária de Proteína , Internalização do Vírus
16.
Int J Prosthodont ; 22(4): 351-3, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19639070

RESUMO

The aim of this study was to measure in vitro retention of cast gold crowns cemented with traditional and resin cements. Forty-eight human molars were prepared on a lathe to produce complete crown preparations with a consistent taper and split into six groups, eight crowns in each group. Crowns were cast in a high-gold alloy and then cemented. After 24 hours, the retention force (N) was recorded and mean values were analyzed by one-way analysis of variance and the Fisher post-hoc least significant difference (PLSD) multiple comparisons test (a = .05). Failure sites were examined under 3100 magnification and recorded. Mean values (SD) for each group in increasing order of retention force were: Harvard Cement: 43 N (27), TempoCem: 59 N (16), PermaCem Dual: 130 N (42), RelyX Luting Cement: 279 N (26), Contax and PermaCem Dual: 286 N (38), and TempoCem with Contax and PermaCem Dual: 340 N (14). The Fisher PLSD interval (P = .05) for comparing cements was 29 N. Zinc-phosphate cement and provisional resin cements had the lowest retention forces. Resin cement with a bonding agent and the hybrid-ionomer cement had similar retention forces. Resin cement with a bonding agent applied after use of a provisional resin cement had a significantly higher retention force than the other cements tested.


Assuntos
Cimentação/métodos , Coroas , Cimentos Dentários/química , Retenção em Prótese Dentária , Ligas de Ouro/química , Cimentos de Resina/química , Resinas Compostas/química , Falha de Restauração Dentária , Análise do Estresse Dentário/instrumentação , Cimentos de Ionômeros de Vidro/química , Humanos , Teste de Materiais , Dente Molar/patologia , Estresse Mecânico , Propriedades de Superfície , Temperatura , Fatores de Tempo , Preparo Prostodôntico do Dente , Água/química , Cimento de Fosfato de Zinco/química
17.
Tex Dent J ; 126(4): 312-9, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19472550

RESUMO

By the 1980's, bonding of orthodontic brackets had become the routine technique for attaching fixed appliances to teeth, replacing the need to fit and cement bands on each tooth (1). This modification in appliance attachment revolutionized orthodontics. Before, each tooth required a band. This meant a band must be fitted, have a bracket welded to it, and be cemented onto each tooth. Not only was this process time consuming and frustrating, but it meant 4 to 6 millimeters of space per arch was needed to seat the bands. Many cases that perhaps could have been treated without tooth extraction ended up needing extractions to accommodate the band space.


Assuntos
Colagem Dentária , Cimentos Dentários/química , Braquetes Ortodônticos , Condicionamento Ácido do Dente/métodos , Animais , Bovinos , Análise do Estresse Dentário/instrumentação , Teste de Materiais , Distribuição Aleatória , Cimentos de Resina/química , Saliva , Resistência ao Cisalhamento , Estresse Mecânico , Propriedades de Superfície , Fatores de Tempo , Água/química
18.
Proc Natl Acad Sci U S A ; 105(10): 3739-44, 2008 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-18322015

RESUMO

Most antibodies induced by HIV-1 are ineffective at preventing initiation or spread of infection because they are either nonneutralizing or narrowly isolate-specific. Rare, "broadly neutralizing" antibodies have been detected that recognize relatively conserved regions on the envelope glycoprotein. Using stringently characterized, homogeneous preparations of trimeric HIV-1 envelope protein in relevant conformations, we have analyzed the molecular mechanism of neutralization by two of these antibodies, 2F5 and 4E10. We find that their epitopes, in the membrane-proximal segment of the envelope protein ectodomain, are exposed only on a form designed to mimic an intermediate state during viral entry. These results help explain the rarity of 2F5- and 4E10-like antibody responses and suggest a strategy for eliciting them.


Assuntos
Anticorpos Anti-HIV/imunologia , Proteína gp41 do Envelope de HIV/imunologia , HIV-1/imunologia , Proteínas Recombinantes de Fusão/imunologia , Anticorpos Monoclonais/imunologia , Sítios de Ligação de Anticorpos , Antígenos HIV/imunologia , Proteína gp41 do Envelope de HIV/química , Cinética , Ligantes , Testes de Neutralização , Estrutura Quaternária de Proteína , Estrutura Secundária de Proteína , Proteínas Recombinantes de Fusão/química , Ressonância de Plasmônio de Superfície , Produtos do Gene env do Vírus da Imunodeficiência Humana/química
20.
EMBO J ; 25(20): 5026-35, 2006 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-17006538

RESUMO

The trimeric HIV/SIV envelope glycoprotein, gp160, is cleaved to noncovalently associated fragments, gp120 and gp41. Binding of gp120 to viral receptors leads to large structural rearrangements in both fragments. The unliganded gp120 core has a disordered beta3-beta5 loop, which reconfigures upon CD4 binding into an ordered, extended strand. Molecular modeling suggests that residues in this loop may contact gp41. We show here that deletions in the beta3-beta5 loop of HIV-1 gp120 weaken the binding of CD4 and prevent formation of the epitope for monoclonal antibody (mAb) 17b (which recognizes the coreceptor site). Formation of an encounter complex with CD4 binding and interactions of gp120 with mAbs b12 and 2G12 are not affected by these deletions. Thus, deleting the beta3-beta5 loop blocks the gp120 conformational change and may offer a strategy for design of restrained immunogens. Moreover, mutations in the SIV beta3-beta5 loop lead to greater spontaneous dissociation of gp120 from cell-associated trimers. We suggest that the CD4-induced rearrangement of this loop releases structural constraints on gp41 and thus potentiates its fusion activity.


Assuntos
Antígenos CD4/química , Proteína gp120 do Envelope de HIV/química , Proteína gp41 do Envelope de HIV/química , HIV-1/química , Modelos Moleculares , Complexos Multiproteicos/química , Anticorpos Monoclonais/química , Anticorpos Monoclonais/metabolismo , Antígenos CD4/genética , Antígenos CD4/metabolismo , Produtos do Gene env/química , Produtos do Gene env/genética , Produtos do Gene env/metabolismo , Proteína gp120 do Envelope de HIV/genética , Proteína gp120 do Envelope de HIV/metabolismo , Proteína gp41 do Envelope de HIV/genética , Proteína gp41 do Envelope de HIV/metabolismo , HIV-1/genética , Humanos , Complexos Multiproteicos/genética , Complexos Multiproteicos/metabolismo , Ligação Proteica/genética , Estrutura Quaternária de Proteína , Estrutura Secundária de Proteína , Relação Estrutura-Atividade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...